How to set the light cycle of the light incubator?

As an important equipment in experiments such as plant germination, seedling cultivation, and microbial cultivation, the light incubator has been receiving wide attention. However, the incubator equipment manufactured by different manufacturers has different function parameter settings. Let's take an example below to understand how the light incubator is cycled!

Light incubator


First, power on the light incubator, turn on the power switch in the "ON" position, then the power indicator light is on, press the "power" button, all the digital display "888……" indicator lights are all on, after displaying 4S, the control enters into operation status. For example: the equipment operation cycle is 5 cycles, each cycle is three periods, the first period is daytime, 8 hours, 6 levels of illuminance, temperature control is 25℃; the second period is 16 hours, night , 0 illuminance, temperature control at 4 ℃.
Specific parameter settings of the light incubator: Long press the cycle key to enter the cycle setting, at this time, press the increase key "∧" or decrease key "∨" to set the cycle to 5, and then long press this key to exit; long press to set/query Press the key for 2 seconds to enter the segment selection setting state, and the setting light is on. Periodic window display: "cH", the hour window flashes. Similarly, the number of segments can be set to "2" through the increase key "∧" or the decrease key "∨". Continue to click the setting query button to enter the parameter setting of each time period. The period window display segment "01" is set to 8, which is also modified by the increase key "∧" or the decrease key "∨". Then set the query key at a few points, the minute window flashes, set to 0 minutes, then click the set query button, the temperature window flashes, and set the temperature to 25℃, then click the set query button to set the illuminance. The segment illuminance is set to 6 levels. The parameters of the stage are set. Then continue to click the setting query button to enter the second stage of parameter setting. As with the above steps, set the parameters to 16 hours at night, illuminance to level 0, and temperature control to 4°C. After setting, press the query key to return to the segment parameter setting, long press the setting query key to exit the setting, and the parameter setting is now complete.

Drill Rods

Drill Rods,Rock Bolting Rig Rods,Hydraulic Hammers Rods For Excavators,Hydraulic Hammer Breaker Rods

Jinan Lingong Mining& Rock Technology Co., Ltd. , https://www.lgmrt.com